2018-04-20 by Jun Tai
First, the reason
1. The click speed is too low (below 500r/min), or the steering is reversed;
2, the amount of oil is not enough, the oil level is too low, or the suction pipe is blocked by debris;
3, the oil viscosity is too high, the oil absorption resistance increases;
4. The clearance between the blade and the rotor slot is too small, so that the blade is not flexible in moving in the slot;
5. Poor contact between the oil distribution plate and the casing, so that the high and low pressure oils communicate with each other;
6. The pump body has casting defects such as sand particles and shrinkage holes, so that high and low pressure oils can communicate with each other;
Second, exclusion method
1. Check the direction of rotation and the speed of rotation or replace the motor;
2. Check the oil level, add enough oil, and remove the impurity and dirt from the oil suction pipe;
3. Use No. 20 mechanical oil or special hydraulic oil with appropriate viscosity;
4. Re-grind the blade to maintain a suitable fit clearance;
5. Re-grind the two contact planes of the oil distribution plate, and the parallelism should be kept within 0.005mm;
6. Replace the new pump body.
Teacher's Day: Salute to every guide in life!
2024-09-10Juntai aluminum shell motor: the cost-effective choice!
2024-08-15Craftsmanship Precision Casting Wedding Seal Gold Item | Juntai Hydraulic Capping Ceremony Successfully Completed!
2024-08-12On Army Day, we pay tribute to the glorious years of August 1st!
2024-08-01Juntai internal mesh gear pump: energy-saving first choice!
2024-07-31Juntai hydraulic pump: the source of power, energy-saving first choice!
2024-07-18What is the difference between low-priced hydraulic oil and genuine hydraulic oil?
2018-06-29Common faults in the operation of hydraulic components
2018-06-29There are several points in the role of the hydraulic cylinder guard!
2018-06-29Analysis of the cause of the leakage of the hydraulic system
2018-06-29